Size gutters and calculate materials needed

Roof & Gutter Details

Plan area draining to gutters

Default: 75 mm/hr

Enter the actual largest pitch-adjusted tributary area. It cannot be below the even share; leave blank only when outlets divide the effective area equally.

5% typical

Results

Enter details and click Calculate to see results

UKUK Building Regulations

References & Sources

Standards Cited
  • Approved Document H โ€” Drainage and waste disposal โ€” H3 rainwater drainage
    H3 Table 1 effective-area pitch factors and Table 2 gutter/outlet sizing
  • BS EN 12056-3 โ€” Gravity drainage systems inside buildings โ€” Roof drainage, layout and calculation
    Gutter sizing, flow capacity, and downpipe design
Formulas Used
  • UK effective roof area: A_effective = A_plan ร— (1 + 0.5 ร— tan(roofPitch))
    Source: Approved Document H H3, Table 1 pitch-factor anchors โ€” Reproduces the published factors 1.29 at 30ยฐ, 1.50 at 45ยฐ, and 1.87 at 60ยฐ. Over 70ยฐ, Table 1 requires an elevational-area method, so this plan-area calculator fails closed.
  • Required flow rate: Q = effectiveRoofArea ร— rainfallIntensity / 3600
    Source: Approved Document H / BS EN 12056-3 โ€” Q in litres/second, area in mยฒ, rainfall in mm/hr
  • Number of brackets: brackets = ceil(gutterRun / bracketSpacing) + 1
    Source: BS EN 12056-3
Key Assumptions
  • Design rainfall: 75 mm/hr for UK (BS EN 12056-3) โ€” BS EN 12056-3
  • Half-round and ogee profiles available in 75-150 mm widths โ€” Industry standard
  • Bracket spacing: 900 mm maximum โ€” BS EN 12056-3