how manybricks
Home/DPC/Calculator

Damp Proof Course (DPC) Calculator

Length, width, laps, rolls and basic height check

Inputs

The calculator derives required DPC width from wall thickness and skins; preset widths are shown for reference only.

Note: This is an estimating tool. Verify DPC selection and detailing with current standards and manufacturer data.

Results

Enter your wall details then click Calculate.

UKUK Building Regulations

References & Sources

Standards Cited
  • Approved Document C โ€” Building Regulations Approved Document C: Site preparation and resistance to contaminants and moisture
    Requires DPC to be installed at minimum 150 mm above external ground level to prevent rising damp; defines moisture resistance requirements for walls
  • BS 8215 โ€” Code of practice for design and installation of damp-proof courses in masonry construction
    Provides detailed guidance on DPC selection, lap lengths (minimum 150 mm), installation methods, and compatibility with mortar and wall types
  • BS 6398 โ€” Specification for bitumen damp-proof courses for masonry
    Specifies material properties, dimensions, and performance requirements for bitumen-based DPC products
  • BS 8102 โ€” Code of practice for protection of below ground structures against water from the ground
    Relevant to vertical DPC in cavity walls and below-ground moisture protection strategies
Formulas Used
  • DPC width (single skin): width = wall thickness + 20 mm
    Source: BS 8215 โ€” Extra 10 mm overhang each side to ensure full coverage of the mortar bed
  • DPC width (cavity wall): width = (wall thickness x 2) + 25 mm
    Source: BS 8215 โ€” Allows for cavity overlap in double-skin construction
  • Number of laps: laps = ceil(wall length / effective roll length) - 1
    Source: BS 8215 โ€” Effective roll length = roll length minus lap overlap (typically 150 mm). Minimum 150 mm lap at all joints
  • Mortar bed volume: V = wall length x DPC width x bed depth (5 mm)
    Source: BS 8215 โ€” DPC is bedded in mortar; 5 mm bed joint depth is standard
Key Assumptions
  • Minimum DPC height of 150 mm above external finished ground level โ€” Approved Document C
  • Lap length of 150 mm at all DPC joints โ€” BS 8215
  • Standard DPC roll lengths of 10 m, 20 m, and 30 m are assumed for roll quantity calculation โ€” Manufacturer standard sizes
  • Vertical DPC requirement for cavity walls estimated at 10% of wall length (for door/window reveals) โ€” BS 8215 / building practice estimate
  • Cost estimate uses approximate rates of GBP 2.50/m (narrow) to GBP 4.00/m (wide > 200 mm) โ€” actual prices vary โ€” Industry estimate