CACalifornia Building Code (Title 24)
References & Sources
Standards Cited
- AWC DCA 6 β American Wood Council Prescriptive Residential Wood Deck Construction Guide
Provides guidance on joist spacing, board thickness, gap sizes, and structural requirements for timber decking - AWPA U1 β Use Category System: User Specification for Treated Wood
Guidance on timber treatment and preservation for external decking exposed to weather
Formulas Used
- Deck Area:
A = deckWidth x deckLength
Source: Standard geometry - Boards Across Width:
boards = ceil(deckWidth_mm / (boardWidth + gapSize))
Source: AWC DCA 6 decking guidance β Effective board width includes the gap between boards - Joists Required:
joists = ceil(deckLength_mm / joistSpacing) + 1
Source: AWC DCA 6 decking guidance β First joist at 0mm, then at each spacing interval - Screws Needed:
screws = boardsNeeded x joistsRequired x 2
Source: AWC DCA 6 decking guidance β 2 screws per board per joist intersection - Linear Metres of Board:
linearMetres = boardsNeeded x deckLength
Source: Standard calculation
Key Assumptions
- Recommended joist spacing: 300mm for boards <20mm thick, 400mm for <25mm, 450mm for <32mm, 600mm for >=32mm β AWC DCA 6 decking guidance
- Gap between decking boards typically 3-6mm for drainage and expansion β AWC DCA 6 decking guidance
- 10% wastage allowance for cuts at board ends β Industry standard practice
- 2 screws per board at each joist crossing point β AWC DCA 6 decking guidance